SMAN® Refrigerant Manifold 4-port with Built-in Vacuum Gauge

Fieldpiece offers state-of-the-art digital manifolds.

- Support A1, A2L and A3 refrigerants;

- Integrate with Job Link® tools;

- Temperature compensated system tightness test;

- Weather resistant IP55 heavy duty design.

Our digital manifold can work with complex HVACR systems and integrate with the Job Link® tools, ensuring you have all the information you need in the palm of your hand.

Where to buy
Where to buy

Overview

Four reasons why you need the SM482VINT

1. Integrate with Job Link® tools

The wireless SM482VINT is the heart of every job as the Digital Manifold. All the Job Link® tools can be connected to the SM482VINT and with a 300m wireless range, you can find real-time, accurate measurements of all the Job Link® tools right on your Digital Manifold. Plus, you now have the option to connect a third JL3RH Psychrometer directly to the manifold. The on-board data logging feature streamlines your job and makes sure you can provide the customers with all the answers they need.

2. Support A1, A2L and A3 refrigerants

The SM482VINT has been designed to work with low GWP refrigerants and blends to comply with F-gas regulations. This high-tech Digital Manifold does not only help you do your work easier, faster, and better, but it also supports the environment.

3. Reliable, accurate, and personalized

Thanks to the temperature compensated system tightness test function, you never have to worry about inaccurate measurements when pressure testing a system. On top of that, the built in vacuum gauge provides you with all the vacuum related information you need to know. Plus, the SM482VINT is perfect for every technician with the language support of 12 total languages!

4. Heavy duty design

Robust and reliable. The improved manifold block with separated holders and ports for more durability, reinforced hook, an updated IP55 water resistance rating, and impact resistant light up screen ensure the SMAN® is able to withstand any conditions so you can keep doing your job easier, faster, and better.

Specifications

Product

  • Display: LCD (12.7 cm diagonal)
  • Backlight: Blue (adjustable duration)
  • Low Battery Indication: is displayed when the battery voltage drops below the operating level.
  • Over Range Display: OL for pressure, - - - - for temperature
  • Auto Power Off: 30 minutes of inactivity (adjustable)
  • Maximum Manifold Pressure: 5998 kPa (870 Psig)
  • Battery Type: 6 x AA alkaline
  • Battery Life: 405 hours typical
  • (without vacuum, backlight, and wireless)
  • Radio Frequency: 2.4 GHz
  • Wireless Range: 300 meters line of sight.
  • Distance decreases through obstructions.
  • Data Port: USB-C (for extracting data logs or updating firmware)
  • Operating Environment: -10°C to 50°C at <75% RH
  • Storage Environment: -20°C to 60°C at <80% RH (with battery removed)
  • Temperature Coefficient: 0.1 x (specified accuracy) per °C (-10°C to 18°C, 28°C to 50°C)
  • Weight: 1.8 kg
  • Water Resistant: Tested to IP55

Included in package

  • SMAN® Refrigerant Manifold (4 Port)
  • (1) ANC82 Padded, Easy-Open Case
  • (2) TC24 Type K Pipe Clamp Thermocouples
  • (1) ATA1 Type K Bead Thermocouple w/Clip
  • (2) 5/16” Spare Hose Holder Fittings
  • (6) AA Alkaline Batteries


Refrigerants:

New refrigerants are continually being added so be sure to check the latest firmware.

R11, R12, R13, R22, R23, R32, R113, R114, R115, R116, R123, R124, R125, R134A, R236FA, R245FA, R290, R401A, R401B, R402A, R402B, R403B, R404A, R406A, R407A, R407C, R407F, R407H, R408A, R409A, R410A, R413A, R414A, R414B, R416A, R417A, R417C, R420A, R421A, R421B, R422A, R422B, R422C, R422D, R424A, R427A, R428A, R434A, R438A, R448A, R449A, R450A, R452A, R452B, R453A, R454B, R458A, R500, R501, R502, R503, R507A, R508B, R513A, R600, R600A, R601, R601A, R744*, R1233ZD, R1234YF, R1234ZE

*Maximum pressure: 870 Psig (6000 kPa)

Media

Get to know the SM482VINT | Fieldpiece Europe

Get to know the SM482VINT | Fieldpiece Europe

SMAN®: How To Select Your Language | Fieldpiece Europe

SMAN®: How To Select Your Language | Fieldpiece Europe

Frequently asked questions

What other Fieldpiece wireless products connect wirelessly to the manifold?
The SM482VINT and SM382VINT are compatible and can connect wirelessly to the following: - JL3RH Psychrometer - JL3PC Pipe Clamp - JL3LC Large Pipe Clamp - SRS3 Weighing Scales - MG44 Vacuum Gauge - SR47 Weighing Scales
How do I clean my manifold?

Cleaning the Sensors in the manifold over time is required, the pressure sensors inside the manifold may become contaminated with dirt, oil, and other contaminants in normal operational use. To do so, please follow the guide below: 

  1. 1. Never use an object such as a cotton swab to clean the sensor, you may cause damage to the sensor.
  2. 2. Open all valves and cap all the ports except for the VAC port on the SM482VINT, or the central port on the SM382VINT.
  3. 3. Drop enough Isopropyl (rubbing) alcohol into the VAC/middle port using an eye dropper or funnel so that it can flush out contaminants.
  4. 4. Cap VAC/middle port and gently shake your Manifold upside down to clean sensor.
  5. 5. Turn right side up. Open a port to pour out the rubbing alcohol and open all ports to allow sensors to dry out. Drying usually takes about an hour. Repeat if necessary if issues persist.
Can I use the SM382VINT/SM482VINT with A2L and A3 refrigerants?
The manifold has a list of over 70 common refrigerants used in refrigeration and air conditioning, and this includes A2L and A3 refrigerants. For the full list of refrigerants visit the product page.
Why does my vacuum pressure jump up when I turn off my vacuum pump?
The moisture inside the system is still boiling off and is no longer being taken out or compensated for by the vacuum pump. There could be oil that is holding moisture inside either the hose leading to the manifold or inside the block of the manifold.
Why does my vacuum pressure jump up when I close my high side & low side?
You have isolated the micron gauge from the system, you are now only reading what is inside your manifold and the hose connected to vacuum pump.
What is the operating pressure range?
29" HgV to 870 psig/ 60 bar. 1-10.000 microns.
Why does my superheat/subcooling read -o/l?
You may have a negative degree of superheat or subcooling. To check this see below: ...................................................................................................................................................................................................................................................................................................................................................... 1. Plug in thermocouple into LLT port and change refrigerant to R113 to check to see if the manifold calculates subcooling. ...................................................................................................................................................................................................................................................................................................................................................... 2. Plug in thermocouple into LLT port and change refrigerant to R407F to check to see if the manifold calculates superheat.
Why is my vacuum pressure inaccurate?
Vacuum pressure being inaccurate is a sign of oil holding moisture either inside the block of the manifold or in the hoses. The oil in your vacuum pump may also need to be changed. Clean sensor periodically with rubbing alcohol.
How to perform advance pressure calibration?
Advanced Calibration: ...................................................................................................................................................................................................................................................................................................................................................... 1. Plug in thermocouple into SLT port. ...................................................................................................................................................................................................................................................................................................................................................... 2. Calibrate Thermocouple to Ice water 0°C. ...................................................................................................................................................................................................................................................................................................................................................... 3. Tape thermocouple to side of refrigerant tank that has been sitting at a constant temperature for 24-48 hours. ...................................................................................................................................................................................................................................................................................................................................................... 4. Put a brass cap on SLT and another one on LLT and open up both valves. ...................................................................................................................................................................................................................................................................................................................................................... 5. Hook up refrigerant tank to manifold and open the tank. (Ensure that the Vac valve is closed on manifold before opening refrigerant tank. 4 port manifold only.) ...................................................................................................................................................................................................................................................................................................................................................... 6. Open refrigerant tank. ...................................................................................................................................................................................................................................................................................................................................................... 7. Select the type of refrigerant being used for this on the manifold. ...................................................................................................................................................................................................................................................................................................................................................... 8. Open up the Ref port on manifold (4 port manifold only). Both high and low pressures should read the same. ...................................................................................................................................................................................................................................................................................................................................................... 9. Press “Test Cal” button. Both pressure sensors should read “GOOD”."
What is the wireless range?
300 meters line of sight.
Which refrigerants are compatible with the SM382VINT & SM482VINT manifolds?
A full list of refrigerants can be found in our user manual, under specifications. Additional refrigerants can be uploaded to the manifold via regular software updates. Check our Software Update page on the website.
How many wireless tool can I connect to my Digital Manifold at the same time?
The SMAN® refrigerant manifold can connect to multiple Job Link® tools and display those values on the screen of the manifold. The number of tools that can be connected at the same time are: 3 x JL3RH Psychrometer 2 x JL3PC Pip Temperature Clamps 2 x JL3LC Large Pipe Temperature Clamps 1 x MG44 Vacuum Gauge 1 x SRS3 or SR47