Fieldpiece VP633 Gecomprimeerd 0209863 Fieldpiece VP633 Gecomprimeerd 0209863

Bomba de vácuo 6CFM com classificação ATEX

VP633
What's the difference between the VP633 / VP833 / VPX33?
VP633: 6 CFM 170 l/min - 15 kg - Motor AC - Dupla voltagem VP833: 8 CFM 225 l/min - 13 kg - Motor DC - 110V ou 230V VPX33: 10 CFM 280 l/min - 12 kg - motor DC com revestimento EPO** - 110V ou 230V
Why is there vapor coming out of the pump?
It is normal for the pump to emit vapor when pumping on a chamber from atmosphere. Since all the air that is removed from the chamber by the pump moves through the oil in the oil reservoir, some of that oil is vaporized when a lot of air is moving through it. When the pressure in the chamber is reduced to a few hundred torr, the oil vapor will be reduced.
How often do I need to change the oil?
We recommend to empty or replace oil at the end of every usage. Don’t leave old oil in the machine. Store the pump and oil in dry clean areas for longest life. The oil can lose its sealing properties if left uncovered. Keep the oil sealed until it’s ready for use.
Do I have to use fieldpiece oil?
No, you can use any manufacturer's vacuum pump oil, however fieldpiece oil is optimized for our vacuum pumps and has a specific viscosity for maximum performance.
Why is my oil cloudy?
Excessive moisture is present in the oil indicating that the oil needs to be replaced.
How do I know that my vacuum pump can pull down sufficiently?
Perform this test to ensure the vacuum pump and your micron gauge are working properly. ...................................................................................................................................................................................................................................................................................................................................................... 1. Connect your vacuum gauge directly to a port on the vacuum pump. ...................................................................................................................................................................................................................................................................................................................................................... 2. Seal the 3 other ports. ...................................................................................................................................................................................................................................................................................................................................................... 3. Ensure the gas ballast is closed. ...................................................................................................................................................................................................................................................................................................................................................... 4. Turn on the vacuum pump to create a vacuum at your gauge. ...................................................................................................................................................................................................................................................................................................................................................... If your gauge measures below 200 microns within 1 minute, you know the vacuum pump and your micron gauge are working correctly. If your gauge does not reach 200 microns, there is a problem with your gauge, the vacuum pump, or both.
What are the sizes of the ports?
The port sizes from left to right are 1/4”, 1/2”, 3/8”, 3/8“.
What is the gas ballast and when do I use it?
A gas ballast valve will allow a flow of air into the final part of the compression cycle and allow the vapor to be expelled without condensation or affecting the pump's overall performance. Using the gas ballast valve on the initial pull down helps the pump run smoothly and keeps the oil in good condition.
A bomba de vácuo pode aspirar sistemas de refrigerantes NH3?
Não certificamos a bomba contra sistemas NH3, no entanto, desde que o sistema esteja completamente vazio de Refrigerante antes da evacuação, pode ser utilizada em sistemas NH3.
Does the Vacuum pump have an anti-suck back oil system?
Yes, The Fieldpiece Vacuum Pumps features a non-mechanical ‘anti-oil suck back’ system which when the machine loses power, will ensure that the oil in the vacuum pump does not migrate into the system or the hose lines. We achieve this by having an ‘open-air’ valve that is sealed when the machine is running, but then slowly opens up to atmospheric pressure when the machine loses power or is switched off. The issue we solve with this feature is the oil-suck back issue which can be very damaging and time consuming to the system should this happen.
What is the final recovery vacuum?
The final recovery vacuum is 14.9" HG
What type of oil is used with the machine?
Mineral oil
Quantos estágios têm as bombas de vácuo?
VP633/VP833/VPX33 tem 2 estágios
A bomba de vácuo pode puxar vácuo para sistemas de refrigerante A3?
Sim, a bomba de vácuo pode ser utilizada em segurança com todos os sistemas de refrigerantes A3 e tem Classificação ATEX.