Fieldpiece MR45 06212
Fieldpiece MR45 06213
Fieldpiece Productshoot Liike Gecomprimeerd01241 09579
MR45 recovery machine
MR45 recovery machine
Fieldpiece MR45 06212
Fieldpiece MR45 06213
Fieldpiece Productshoot Liike Gecomprimeerd01241 09579
MR45 recovery machine
MR45 recovery machine

Digital Recovery Machine UK

Our MR45UK is the highest performance recovery machine in its class on the market.

- Automatically adjust motor performance to gain time;

- Lightweight design of only 10kg; & A2L compatible;

- Easy to use because of the single dial valve and LCD display.

Our Recovery Machine ensures that you can work as efficiently and quickly as possible at every job.

Where to buy
Where to buy

Overview

Three reasons why you need the MR45UK

1. Adjust motor performance automatically

With on-board system monitoring, this recovery machine is able to automatically adjust motor performance from 2000 to 3000 rpm to handle liquid and run twice as fast on vapor. This means that liquid slugging is minimized and vapor recovery is maximized, and with a 1,23 kg per minute recovery speed, the MR45UK makes the recovery part of every job super quick.

2. Lightweight and portable

With a powerful presence on the job site, the MR45UK is still a very lightweight and portable player that is compatible with A2L refrigerants. With only 10kg to carry, the MR45UK can easily be taken anywhere on site.

3. Easy-to-use

Because of the single dial valve that the MR45UK comes equipped with, you no longer have to think about three or four valves in one system. Simply turn the dial to the setting you need and you’re good to go. And not to forget, the measurements are easily viewable on the LCD display, ensuring you can read the information you need anywhere.

Specifications

Product

  • Display: 2 x 10000 count LCD with status messages
  • Backlight: Blue color
  • Measurement rate: 3.3 times per second, nominal
  • Auto-stop Levels: 0 bar (default), -0.34 bar, -0.68 bar,
    (0 psig, -10 inHg, -20 inHg, 0 kPa, -25 cmHg, -50 cmHg)
  • Input Port Pressure Sensor Range:
    -1 bar to 41 bar (-30 inHg to 600 psig)
  • Output Port Pressure Sensor Range:
    -1 bar to 41 bar (-30 inHg to 600 psig)
  • High Pressure Cutoff: 38.5 bar, 3850 kPa (558 psig), nominal
  • Pressure Relief Valve: 42 bar, 4.2 MPa (609 psig), nominal
  • Resolution and Units: 0.05 bar (2 cmHg), 0.01 MPa (2 cmHg),
    0.05 bar (0.03 bar) 5 kPa (2 cmHg), 1 psig (1” Hg)
  • Pressure Sensor Accuracy:
    ± 0.02 bar, ± 1.3 cmHg, ± 0.5 inHg (Vacuum)
    ± (0.6% of reading + 0.14 bar), ± (0.6% of reading +2 psig)
  • Final Recovery Vacuum: -0.51 bar, -38 cmHg, -14.9 inHg
  • Compressor: Twin cylinder reciprocating (oil-less)
  • DC Motor: 746 Watt (variable smart speed)
  • Power Source: 95 to 130 VAC @ 50 Hz 1 phase
  • Nominal Current Draw: 12.0 A
  • Valve: Single dual-route ball valve
  • Input Port Filtration: 9 mm mesh screen, stainless
  • Noise: Sound pressure level <70 db(A)
  • Dimensions: 376 mm x 250 mm x 344 mm (14.8” x 9.8” x 13.5”)
  • Weight: 10 kg (22 lbs)
  • Operating Environment: 0°C to 43°C (32°F to 109°F)
  • Storage Environment: -20°C to 60°C (-4°F to 140°F)
  • Approved Refrigerants: R12, R22, R32*, R134A, R143A*, R401A,
    R401B, R401C, R402A, R402B, R404A, R407A, R407B, R407C,
    R407D, R408A, R409A, R410A, R448A, R452A, R454B*, R500, R502,
    R507, R509, R1234YF*, R1234ZE*
    * Class A2L (mildly flammable) refrigerants

Included in package

  • MR45UK - Digital Recovery Machine
  • Appropriate plug based on country

Media

MR45 Digital Recovery Machine: Throttle feature | Fieldpiece Europe

MR45 Digital Recovery Machine: Throttle feature | Fieldpiece Europe

MR45 Digital Recovery Machine: Variable Speed Motor | Fieldpiece Europe

MR45 Digital Recovery Machine: Variable Speed Motor | Fieldpiece Europe

MR45 Digital Recovery Machine: Single dial valve | Fieldpiece Europe

MR45 Digital Recovery Machine: Single dial valve | Fieldpiece Europe

Frequently asked questions

Is the Recovery Machine dual voltage?
The MR45INT is 230v only, however we do sell the MR45UK which is 110v only.
How do I clean my recovery machine?
1. Wipe with damp cloth to clean the exterior. Do not use solvents. 2. When the mesh screen filter becomes dirty and clogged, it means it’s keeping your MR45INT/MR45UK working well and protected from contaminants entering the machine and causing damage. You need to clean or replace this screen often.
What is the high pressure cut-out set to?
The High pressure cut out is set to 550 psi / 38 bar.
Do I need to use a filter drier?
We recommend to use a filter drier on the input port and change it often to protect the MR45INT/MR45UK from contaminated refrigerants.
Is the MR45INT/MR45UK A3 approved?
No, the MR45INT/MR45UK is not certified for A3 refrigerants, therefore it cannot be used with any combustible refrigerants.
Is the MR45INT/MR45UK A2L approved?
Yes, the MR45INT/MR45UK is A2L ready and can be used with refrigerants such as R32, R1234ZE and R1234YF.
What is the over pressure protection on the recovery machine?
The High-pressure cut off switch activates at 38 bar (550 psig).
At what negative pressure will the recovery machine cut off?
20"hg negative pressure or 50cmHg negative pressure is the final recovery value when the machine will stop automatically.