Fieldpiece VPX33 Gecomprimeerd 0209864
Fieldpiece VP833 Gecomprimeerd 0209909 min
Fieldpiece VPX33 Gecomprimeerd 0209888
Fieldpiece VPX33 Gecomprimeerd 0209882
Fieldpiece VPX33 Gecomprimeerd 0209864
Fieldpiece VP833 Gecomprimeerd 0209909 min
Fieldpiece VPX33 Gecomprimeerd 0209888
Fieldpiece VPX33 Gecomprimeerd 0209882

Bombas de vácuo de 10 CFM com classificação ATEX

Fieldpiece oferece bombas de vácuo de 10 CFM com classificação ATEX de alto desempenho que reduzem o tempo de evacuação.

- Tem classificação ATEX para trabalhar com Refrigerantes A3;

- Mudança Rápida de Óleo RunQuick® para mudar o óleo em menos de 20 segundos;

- Design leve e portátil de apenas 12 kg e até 15 microns de vácuo final;

- 4 Portas em linha para fácil conexão de Mangueiras;

- Compatível com A3 e A2L.


A nossa bomba de vácuo de 10CFM com classificação ATEX foi concebida para efetuar fácil e rapidamente a aspiração de um sistema.

Onde comprar
Onde comprar

Visão geral

Cinco razões pelas quais precisas do nosso VPX33

1. Trabalha em segurança com a nossa bomba com classificação ATEX

Trabalha com Refrigerantes A3? Não precisas de te preocupar! A nossa bomba de vácuo VPX33 tem classificação ATEX, garantindo um funcionamento seguro em ambientes potencialmente explosivos. Esta classificação confirma que a VPX33 é compatível com os refrigerantes A3, permitindo-lhe trabalhar com confiança.


2. Faz o teu trabalho mais rapidamente com o nosso Sistema de Mudança Rápida de Óleo RunQuick™

O óleo limpo é importante. Tu - o técnico - compreendes a importância de um óleo limpo, mas também o incómodo que essa tarefa normalmente acarreta. Com o nosso Sistema de Mudança Rápida de Óleo RunQuick™, eliminámos o inconveniente de mudar o óleo e tornámos possível que troques o óleo da tua bomba de vácuo em 20 segundos ou menos, sem desligar ou perder vácuo. E, através do grande reservatório de óleo, podes ver facilmente o estado do teu óleo num instante. Sem confusão, troca rápida, vácuo rápido. Este é o nosso VPX33.


3. Leve e portátil

Concebido para lidar com as exigências de qualquer trabalho, o VPX33 é suficientemente leve para ser transportado para qualquer lugar no local. Com um peso de apenas 12 kg, esta bomba de vácuo Fieldpiece é leve mas potente - com a capacidade de atingir 15 microns de vácuo final e é compatível com os Refrigerantes A3 e A2L!


4. Quatro portas em linha

Quatro portas em linha para garantir que tens muito espaço para passar facilmente várias Mangueiras. Graças às portas estrategicamente colocadas, as Mangueiras emaranhadas e a desordem à volta da tua bomba de vácuo são coisa do passado. Trabalha de forma eficiente com a nossa VPX33 e conecta facilmente Mangueiras de ¼“, ⅜” e ½”.


5. Lastro de gás fácil de utilizar

Para engatar ou desengatar a válvula de lastro de gás, basta rodar a alavanca para o lado que for necessário. Este sistema de estilo de alavanca garante que podes mudar fácil e rapidamente o lastro de gás, para tornar o teu trabalho mais fácil, mais rápido e melhor.

Especificações

Produto

  • Taxa de fluxo: 10CFM
  • Vácuo máximo nas Portas de Entrada: 15 mícrons
  • Para uso com: Refrigerantes A3, A2L e A1
  • Não deve ser usado com: R-702, R-717
  • Capacidade de óleo: 237ml
  • Compatibilidade do óleo: Óleo para bomba de vácuo Fieldpiece (altamente refinado e optimizado para uma vedação e lubrificação adequadas)
    Números de peça Fieldpiece: OIL8X3, OIL32, OIL128
  • Luz de fundo do óleo: LED azul
  • Drenagem do óleo: Válvula de esfera
  • Tamanhos de Porta: (1) 1/4", (2) 3/8", (1) 1/2"
  • Compressor: Palhetas rotativas, dois estágios
  • Motor: 3/4 HP DC sem escovas
  • RPM: 2500
  • Fonte de alimentação: 110 VAC 50 Hz/ 230 VAC 50 Hz
  • Consumo de corrente nominal: 5A a 110 VAC / 2A a 230 VAC
  • Potência nominal: 550W a 110V, 460W a 230V
  • Classificação de proteção de entrada da unidade: IP20
  • Dimensões: 201 mm x 296 mm x 406 mm
  • Peso vazio: 12 kg
  • Ambiente de funcionamento: 0°C a 40°C

Incluído na embalagem

  • Bomba de vácuo VPX33
  • 2x 237ml de óleo
  • Ficha adequada consoante o país

Media

Get to know the VPX33 | Fieldpiece Europe

Get to know the VPX33 | Fieldpiece Europe

Perguntas mais frequentes

What's the difference between the VP633 / VP833 / VPX33?
VP633: 6 CFM 170 l/min - 15 kg - Motor AC - Dupla voltagem VP833: 8 CFM 225 l/min - 13 kg - Motor DC - 110V ou 230V VPX33: 10 CFM 280 l/min - 12 kg - motor DC com revestimento EPO** - 110V ou 230V
Why is there vapor coming out of the pump?
It is normal for the pump to emit vapor when pumping on a chamber from atmosphere. Since all the air that is removed from the chamber by the pump moves through the oil in the oil reservoir, some of that oil is vaporized when a lot of air is moving through it. When the pressure in the chamber is reduced to a few hundred torr, the oil vapor will be reduced.
How often do I need to change the oil?
We recommend to empty or replace oil at the end of every usage. Don’t leave old oil in the machine. Store the pump and oil in dry clean areas for longest life. The oil can lose its sealing properties if left uncovered. Keep the oil sealed until it’s ready for use.
Do I have to use fieldpiece oil?
No, you can use any manufacturer's vacuum pump oil, however fieldpiece oil is optimized for our vacuum pumps and has a specific viscosity for maximum performance.
Why is my oil cloudy?
Excessive moisture is present in the oil indicating that the oil needs to be replaced.
How do I know that my vacuum pump can pull down sufficiently?
Perform this test to ensure the vacuum pump and your micron gauge are working properly. ...................................................................................................................................................................................................................................................................................................................................................... 1. Connect your vacuum gauge directly to a port on the vacuum pump. ...................................................................................................................................................................................................................................................................................................................................................... 2. Seal the 3 other ports. ...................................................................................................................................................................................................................................................................................................................................................... 3. Ensure the gas ballast is closed. ...................................................................................................................................................................................................................................................................................................................................................... 4. Turn on the vacuum pump to create a vacuum at your gauge. ...................................................................................................................................................................................................................................................................................................................................................... If your gauge measures below 200 microns within 1 minute, you know the vacuum pump and your micron gauge are working correctly. If your gauge does not reach 200 microns, there is a problem with your gauge, the vacuum pump, or both.
What are the sizes of the ports?
The port sizes from left to right are 1/4”, 1/2”, 3/8”, 3/8“.
What is the gas ballast and when do I use it?
A gas ballast valve will allow a flow of air into the final part of the compression cycle and allow the vapor to be expelled without condensation or affecting the pump's overall performance. Using the gas ballast valve on the initial pull down helps the pump run smoothly and keeps the oil in good condition.
A bomba de vácuo pode aspirar sistemas de refrigerantes NH3?
Não certificamos a bomba contra sistemas NH3, no entanto, desde que o sistema esteja completamente vazio de Refrigerante antes da evacuação, pode ser utilizada em sistemas NH3.
Does the Vacuum pump have an anti-suck back oil system?
Yes, The Fieldpiece Vacuum Pumps features a non-mechanical ‘anti-oil suck back’ system which when the machine loses power, will ensure that the oil in the vacuum pump does not migrate into the system or the hose lines. We achieve this by having an ‘open-air’ valve that is sealed when the machine is running, but then slowly opens up to atmospheric pressure when the machine loses power or is switched off. The issue we solve with this feature is the oil-suck back issue which can be very damaging and time consuming to the system should this happen.
What is the final recovery vacuum?
The final recovery vacuum is 14.9" HG
What type of oil is used with the machine?
Mineral oil
Quantos estágios têm as bombas de vácuo?
VP633/VP833/VPX33 tem 2 estágios
A bomba de vácuo pode puxar vácuo para sistemas de refrigerante A3?
Sim, a bomba de vácuo pode ser utilizada em segurança com todos os sistemas de refrigerantes A3 e tem Classificação ATEX.