Information
Fieldpiece VPX7 01189 Fieldpiece VPX7 01189

10 CFM vakuumpumpe

VPX7
Hvad er forskellen mellem VP67 / VP87 / VPX7?
VP67INT: 6 CFM 170 l/min - 13,15 kg - AC-motor - dobbelt spænding ...................................................................................................................................................................................................................................................................................................................................................... VP87INT: 8 CFM 225 l/min - 12,25 kg - DC-motor - 110V eller 230V ...................................................................................................................................................................................................................................................................................................................................................... VPX7INT: 10 CFM 280 l/min - 10,9 kg - DC-motor med EPO-belægning** - 110V eller 230V
Hvorfor kommer der damp ud af pumpen?
Det er normalt, at pumpen udsender damp, når den pumper på et kammer fra atmosfæren. Da al den luft, som pumpen fjerner fra kammeret, bevæger sig gennem olien i oliebeholderen, bliver noget af olien fordampet, når der bevæger sig meget luft gennem den. Når trykket i kammeret reduceres til et par hundrede torr, vil oliedampen blive reduceret.
Hvor ofte skal jeg skifte olie?
Vi anbefaler at tømme eller udskifte olien efter hver brug. Efterlad ikke gammel olie i maskinen. Opbevar pumpen og olien på et tørt og rent sted for at få den længste levetid. Olien kan miste sine forseglingsegenskaber, hvis den efterlades utildækket. Hold olien forseglet, indtil den er klar til brug.
Skal jeg bruge fieldpiece-olie?
Nej, du kan bruge enhver producents vakuumpumpeolie, men Fieldpiece-olie er optimeret til vores vakuumpumper og har en specifik viskositet for maksimal ydelse.
Hvorfor er min olie uklar?
Der er for meget fugt i olien, hvilket indikerer, at olien skal udskiftes.
Hvordan ved jeg, at min vakuumpumpe kan trække tilstrækkeligt ned?
Udfør denne test for at sikre, at vakuumpumpen og din vakuummåler fungerer korrekt. ...................................................................................................................................................................................................................................................................................................................................................... 1. Tilslut din vakuummåler direkte til en port på vakuumpumpen. ...................................................................................................................................................................................................................................................................................................................................................... 2. Forsegl de 3 andre porte. ...................................................................................................................................................................................................................................................................................................................................................... 3. Sørg for, at gasballastventilen er lukket. ...................................................................................................................................................................................................................................................................................................................................................... 4. Tænd for vakuumpumpen for at skabe et vakuum ved din måler. ...................................................................................................................................................................................................................................................................................................................................................... Hvis din måler måler under 200 mikron inden for 1 minut, ved du, at vakuumpumpen og din vakuummåler fungerer korrekt. Hvis din måler ikke når 200 mikron, er der et problem med din måler, vakuumpumpen eller begge dele.
Hvad er størrelsen på portene?
Portstørrelserne fra venstre mod højre er 1/4", 1/2", 3/8", 3/8".
Hvad er gasballast, og hvornår skal jeg bruge den?
En gasballastventil tillader en luftstrøm i den sidste del af kompressionscyklussen og gør det muligt at udstøde dampen uden kondens eller påvirkning af pumpens samlede ydeevne. Brug af gasballastventilen ved den første nedtrækning hjælper pumpen med at køre problemfrit og holder olien i god stand.
Kan vakuumpumpen trække et vakuum til A3/NH3-kølemiddelsystemer?
Vakuumpumperne er certificeret til A2L-kølemiddelsystemer. Vi certificerer ikke pumpen til A3-systemer eller systemer med NH3 - men så længe systemerne er helt tømt for kølemiddel før evakuering, kan den bruges på disse systemer.
Har vakuumpumpen et anti-suck back-oliesystem?
Ja, Fieldpiece-vakuumpumperne har et ikke-mekanisk "anti-oliesug"-system, som, når maskinen mister strømmen, sikrer, at olien i vakuumpumpen ikke vandrer ind i systemet eller slangerne. Vi opnår dette ved at have en "open-air"-ventil, der er forseglet, når maskinen kører, men som langsomt åbner op til atmosfærisk tryk, når maskinen mister strømmen eller slukkes. Det problem, vi løser med denne funktion, er problemet med oliesug, som kan være meget skadeligt og tidskrævende for systemet, hvis det sker.
Hvad er det endelige genvindingsvakuum?
Det endelige opsamlingsvakuum er 14,9" HG
Hvilken type olie bruges sammen med maskinen?
Mineralsk olie
Hvor mange trin har vakuumpumperne?
Alle vores vakuumpumper (VP67/VP87/VPX7) har 2 trin.